Search results

  1. 84 M1008

    Wipers won't turn off automatically

    Ok, I know this has been a problem with GM cars and trucks, but this is the first time I've ever had this happen. Any ideas would be greatly appreciated.
  2. 84 M1008

    Catalytic converters

    We had these "dynos" in N.Y. up until about 15 years ago I believe. They strapped my poor ol 92 square S15 Jimmy to it and revved it untill it passed, failed, or blew up.
  3. 84 M1008

    Catalytic converters

    Hotrod, how is the sniffer inspection done, the put the car on the treadmill? N.Y. stopped that years ago.
  4. 84 M1008

    Catalytic converters

    Wow, still sniffer emissions in California?
  5. 84 M1008

    Catalytic converters

    Some states don't require an emissions test, just a safety inspection. Lights, brakes, ect. I was going to buy a beautiful 96 1500 short bed from NJ, but the cats and o2 sensors were removed. That wouldn't fly in NY. One emission code here is a failure.
  6. 84 M1008

    My other knuckbusting hobby.

    Nothing is cheap for it, LOL! It actually never breaks down, and has never left me anywhere. I've owned four wheel drive trucks all my life, Jeeps, Chevy pickups and Blazers. This thing is unstoppable and would embarrass any other stock 4×4. I am still picking my wrenches out of my nehbors...
  7. 84 M1008

    New guy from Connecticut

    Pics please!
  8. 84 M1008

    Newb from new york

    Nice looking Burb!
  9. 84 M1008

    My other knuckbusting hobby.

    ebay, just Google Mercedes Benz military G wagen.
  10. 84 M1008

    Catalytic converters

    I would just put some shorty headers on it if deleting the cats is the plan. A muffler shop can easily fab up a real duel exhaust system for it.
  11. 84 M1008

    My other knuckbusting hobby.

    My 1988 Danish military 461-240GD . I swapped out the gutless 4 cylinder 240 diesel and installed a 3L 300 SD turbocharged 5 cylinder diesel and a 5 speed.
  12. 84 M1008

    Catalytic converters

    The ECM can be re flashed to 02 delete, depending on what kind of DMV inspection is required should be considered. Re flashing makes the ECM think the o2 sensors are happy.
  13. 84 M1008

    700r4/NP208 and TH400 Compatibility

    Yeah, but you can still break the housing with the torque that engine will make. It's a bit much for a 4×4 truck.
  14. 84 M1008

    700r4/NP208 and TH400 Compatibility

    I would be weary of putting that kind of power through a chain driven transfer case. Perhaps an NP205 may be a better choice. They were also common behind the TH400.
  15. 84 M1008

    700r4/NP208 and TH400 Compatibility

    It's possible to change the shaft to a 32 spline, but it's not worth splitting the case, new gaskets, seals bla bla unless you plan on rebuilding the entire transfer case.
  16. 84 M1008

    700r4/NP208 and TH400 Compatibility

    I bought a new 208/32 spline off eBay a few years ago. They are available .
  17. 84 M1008

    700r4/NP208 and TH400 Compatibility

    The NP208 had two different versions. 27 spline for the700R4 and 32 spline for the Turbo 400. Just my 2 cents, but as old a design as the TH400 is, it is a far superior transmission to the 700R4 no matter what internals you put in it. Probably the best automatic transmission ever made.
  18. 84 M1008

    250 I6 with Offenhauser 3x2s!

    Way cool. I've only seen a few of these. what kind of power do they make?
  19. 84 M1008

    "Rebuilt" 700r4 issues

    Guys like me that have a 6.2 and 4.56 gears appreciate that 400rpm drop.
  20. 84 M1008

    Second Trans failure in 200 miles

    First, always run an external cooler with a 700R4, preferably a fan driven one. The shop more than likely didn't set and adjust the cable properly. I installed my own Monster 700R4 years ago and set and adjust the three times before I was satisfied with the adjustment.
  21. 84 M1008

    Hydroboost noise

    Thanks guys, the power steering lines look like they need replacement. I'm thinking they might be collapsed.
  22. 84 M1008

    Hydroboost noise

    Just when I start it. The usual screaming belts, and every so often I get the buzz. It actually vibrates through the dash and stops along with the belt noise. I don't get it .
  23. 84 M1008

    Hydroboost noise

    Yup, it's full and steers lock to lock with no problem.
  24. 84 M1008

    Hydroboost noise

    My hydroboost unit has a loud buzzing noise sometimes. It happened again yesterday and the strange thing about it is the belts stopped squealing when the buzzing stopped. Belt squealing is common with CUCV trucks and is associated with the dual alternator setup when the engine is cold. Any ideas?
  25. 84 M1008

    TH400 slushy shifting.

    Thanks da_raabi! I'll look into it.

Forum statistics

Threads
45,956
Posts
996,956
Members
39,158
Latest member
cutlerfab
Top