I believe I may have identified part of the issue... the ground wire which connects the fuel sending unit to the body is broken. Does anyone have a photo of where/how the wire connects to the sending unit?
I just looked at this on mine and it is clipped onto the sending unit or lock ring. I'd maybe consider soldering it to a tab on the top of the sending unit.
 

75gmck25

Full Access Member
Joined
Oct 13, 2016
Posts
2,036
Reaction score
1,831
Location
Northern Virginia
First Name
Bruce
Truck Year
1975
Truck Model
K25 Camper Special TH350 NP203
Engine Size
5.7
IIRC, there is a tab on the sending unit and the connector for the ground wire is crimped on it. The other end of the ground wire has a ring terminal for grounding it to the frame.

Bruce
 

bedwards

Full Access Member
Joined
Nov 12, 2016
Posts
192
Reaction score
156
Location
Adger, Al.
First Name
Bryan
Truck Year
1985
Truck Model
c10 Silverado
Engine Size
305
When I cleaned my tanks, one tank came off the jack and yanked the ground wire off. I just cleaned it up with a brush and soldered it to the post where it broke off.
 

Dave M

Banned
Joined
Jul 30, 2019
Posts
602
Reaction score
1,305
Location
Australia
First Name
Dave
Truck Year
1976
Truck Model
C10
Engine Size
454
If you cant solder it back on, drill a 3/16" hole through the tab and fit it off with a crimp terminal.
 

84K30

Full Access Member
Joined
Jul 14, 2019
Posts
156
Reaction score
64
Location
SWPA
First Name
Eric
Truck Year
1984
Truck Model
K30
Engine Size
454
I appreciate all of the responses. Duster dude, if you wouldn’t mind sending me/posting a picture of where exactly the wire connects to the sending unit, I would appreciate it. I don’t recall seeing anything that appeared to be a broken connection/solder when I removed the sending unit to clean the tank.

The ground wire was still bolted to the body when I removed the tank.

I am also considering replacing the sending unit itself since that resolves my broken wire issue and would add a sense of confidence that the pump is new.
 

bucket

Super Moderator
Staff member
Super Moderator
Joined
Aug 3, 2010
Posts
29,087
Reaction score
23,895
Location
Usually not in Ohio
First Name
Andy
Truck Year
'77, '78, '79, '84, '88
Truck Model
K5 thru K30
Engine Size
350-454
It doesn't matter where the ground wire attaches, as long as it attaches somewhere. In the past when the wire has broken off, I've drilled an 1/8" inch hole in a lock ring tab, then installed the wire with an eyelet screwed to that tab with a short #8 screw.
 

dusterdude

Full Access Member
Joined
Oct 7, 2020
Posts
323
Reaction score
335
Location
US
First Name
mark
Truck Year
1985
Truck Model
gmc c15
Engine Size
305
The wire is soldered or somehow attached to the nub on the sender
You must be registered for see images attach


Sent from my LM-X420 using Tapatalk
 

84K30

Full Access Member
Joined
Jul 14, 2019
Posts
156
Reaction score
64
Location
SWPA
First Name
Eric
Truck Year
1984
Truck Model
K30
Engine Size
454
Thank you for posting the picture the attachment point, dusterdude . If I were able to solder/screw the wire back on without dropping the tank again I would absolutely would. However, seeing as how the tank has to come out regardless, I went ahead and ordered a new AC Delco sending unit. I figure that is the route to go since that also eliminates the sender as a factor if my issue persists after resolving the missing ground situation.

I'll keep yinz posted.
 

dusterdude

Full Access Member
Joined
Oct 7, 2020
Posts
323
Reaction score
335
Location
US
First Name
mark
Truck Year
1985
Truck Model
gmc c15
Engine Size
305
You're welcome dude,hope you get it straight

Sent from my LM-X420 using Tapatalk
 

84K30

Full Access Member
Joined
Jul 14, 2019
Posts
156
Reaction score
64
Location
SWPA
First Name
Eric
Truck Year
1984
Truck Model
K30
Engine Size
454
Got around to replacing the passenger fuel tank sending unit today. The new unit included that ground wire I had previously asked about. Went ahead and replaced the rubber fuel hoses between the sending unit and hard lines while I had the tank dropped. I also replaced the fuel tank selector switch.

Even after replacing the items mentioned above, the fuel gauge pegs beyond "F" when I depress and hold the selector switch in the "RH" position. This is with about 5 gallons in the tank. I filled the tank (in the event the float was stuck in the up position) and put fuel stabilizer in it since were about ready for winter here in Pennsylvania. I also figured the tank shouldn't have to come out again since everything has been replaced. When the switch is held in the "LH" position, it reads accurately.

I hear a faint humming noise that I believe to be the fuel tank selector/diverter valve when I depress the tank selector switch. Should this be happening? Does anyone know of a fuse or maybe another ground that may be causing my symptoms, it seems like an electrical issue.

Would it be worth replacing the selector/diverter valve since I do not know if it is operating correctly?

Thank you,
Eric
 

Termite_Delight

Full Access Member
Joined
Feb 17, 2018
Posts
668
Reaction score
1,239
Location
Lanark Ontario Canada
First Name
Andy
Truck Year
1976 1975
Truck Model
K2500 K2500
Engine Size
350 L33
I would check / clean your connections at the valve. You should hear a clunk when it is switched, if not then replace it.
 

84K30

Full Access Member
Joined
Jul 14, 2019
Posts
156
Reaction score
64
Location
SWPA
First Name
Eric
Truck Year
1984
Truck Model
K30
Engine Size
454
The noise it makes is absolutely not a clunk. I'll just go ahead and replace it.

The valve currently on the truck appears to have been replaced with AcDelco U7001 (7 port, 1 of which is unused) The weather pack style 6 pin connector appears to be in good shape. I'll give it a spray with electrical parts cleaner just to be sure.
 

bedwards

Full Access Member
Joined
Nov 12, 2016
Posts
192
Reaction score
156
Location
Adger, Al.
First Name
Bryan
Truck Year
1985
Truck Model
c10 Silverado
Engine Size
305
I would go on and replace the valve itself. The electrical connection goes through the valve.
View media item 9297
 
Last edited:

84K30

Full Access Member
Joined
Jul 14, 2019
Posts
156
Reaction score
64
Location
SWPA
First Name
Eric
Truck Year
1984
Truck Model
K30
Engine Size
454
Upon looking at the 10 day forecast, I came to the conclusion that today was likely going to be the last day that I will be able to drive my truck until spring. I started my truck with the tank selector switch in the R/passenger tank position and let it warm up a few minutes before driving. The gauge read beyond "F" as I mentioned it has since I started troubleshooting this issue. After about a mile driving, the engine began to surge as if it were about to stall.

I depressed the selector switch in position that coincided with the L (driver's side tank), the gauge needle shifted to the "F" position which was accurate. The engine smoothed out and I made it to my destination. When I got home, I played with the switch with the key on but engine off (accessory mode) and noted a dicernible clunk that Termite_Delight mentioned in his post. The fuel tank reading shifted between "F" when the switch was in the left tank position and significantly beyond "F" when in the right tank position.

I have yet to replace the valve but received it via Amazon today and intend to swap it out this Thursday. If the above information give anyone any ideas of what else to check, I would certainly appreciate any suggestions.

Thanks,
Eric
 

84K30

Full Access Member
Joined
Jul 14, 2019
Posts
156
Reaction score
64
Location
SWPA
First Name
Eric
Truck Year
1984
Truck Model
K30
Engine Size
454
Removed the old selector valve today, and measured and cut new rubber fuel lines between the valve and hard lines.

I pre-installed the rubber lines on the new selector valve since I assumed it would be easier to do before it was mounted up to the frame. However, when I went to mount the new valve to the frame, I discovered that I couldn’t get my hand past the rubber hoses to tighten the mounting bolts. When I went to remove the rubber hoses, one of the plastic nipples on the new valve broke.

I have another valve on the way. Hopefully the rest of the install goes smoothly.